The softer foam, cheaper per inch, and unforgiving about where you put it.
Open-cell foam is the low-density version: it sprays in soft, expands a lot, and cures to something closer to a stiff sponge than a plastic panel. It air-seals well and it is the cheapest way to fill a deep cavity with foam. It is also the material that gets misapplied in Massachusetts, because it is vapor-permeable and a cold climate does not forgive a permeable insulation sitting on the wrong side of a wet assembly.
Interior walls and ceilings between conditioned and unconditioned space, sound control between floors in a triple-decker, and large open cavities where depth is free and the budget is not. In an interior application there is no winter cold-side risk, which is exactly why it performs well there.
Because open-cell foam lets water vapor move through it, a cold-climate assembly needs a strategy: a vapor-retarder paint on the warm side, or a layer of closed-cell on the cold face, or enough foam that the dew point never lands inside the cavity. An installer who quotes open-cell for a rim joist or a crawlspace wall without naming the vapor strategy has described half a job.
In a Boston triple-decker the complaint is usually footsteps and conversation, not heat. Open-cell foam in the joist bays takes a meaningful amount of airborne sound out of a floor-ceiling assembly and seals the penetrations that carry the rest. It is not a substitute for a resilient channel detail when a quiet bedroom is the goal, but it is a large share of the way there for the money.
Watertown's stock is largely 1920s to 1950s single-family housing with a growing share of new construction, which means the older half of town has the insulation problems and the newer half usually does not.
In the 1920s stock the rim joist and the attic ceiling are the two surfaces worth doing. Newer houses already have cavity insulation and are more likely to need air-sealing than more material.
Utility: Eversource, under the Mass Save program
For a vented attic with a flat ceiling, open-cell on the ceiling plane plus proper air-sealing is usually the value choice. For an unvented roof deck over a finished attic, closed-cell is the safer material because the deck is the cold surface.
In a cold climate it needs a vapor strategy, which is not always a sheet of plastic. Vapor-retarder paint or a closed-cell layer can do the job. The strategy has to be written down for the specific assembly rather than assumed.
In most occupied spaces it needs a thermal barrier over it for fire code reasons, usually drywall. The installer should tell you what covering the assembly needs before the job starts.