The dense, structural foam. It insulates, air-seals and adds rigidity in one pass.
Closed-cell foam cures to a rigid plastic with a skin you can press a thumb into and not dent. In a Boston house it earns its price where two materials meet a cold surface: the rim joist sitting on the foundation, a crawlspace wall below grade, and any roof deck where the attic has become living space. It is also the spray foam that adds structural strength to a wall assembly, which matters in balloon-framed triple-deckers where the stud bay is doing a lot of the work.
Rim joists, band joists, crawlspace walls, basement walls above and below grade, roof decks on finished attics, and any cavity where the outside face is a cold surface that can condense. In older Boston housing stock the rim joist is usually the biggest single air leak in the envelope, because the framing pocket between floors was never sealed and the sill sits directly on masonry.
It is also the right material over a basement ceiling where the floor above is cold, because it seals joist ends that no batt can reach.
Mask and protect, then prepare the surface: remove loose debris, scrape out old insulation and any failing vapor barrier, and confirm the substrate is dry. Foam sprayed over damp wood traps moisture against the framing, which is how a cheap job becomes a rot repair two winters later.
Foam goes down in lifts. A thick cavity is built up in passes so the heat of reaction does not cook the substrate, and the material is trimmed flush once cured. The installer then checks thickness at several points, because the gap between installed R-value and nominal R-value is almost always a thin spot in a corner.
Closed-cell cures quickly. Most installers allow re-entry within a few hours and treat the job as fully cured overnight. A faint odor for a day is normal. A sharp chemical smell that lasts past 48 hours is not normal, usually means an off-ratio mix, and is the installer's problem to correct rather than something to ventilate away.
Malden's stock is early twentieth century two- and three-families near the center with post-war single-family housing further out. The older buildings are where the big air leaks are.
In these two-families the basement is usually unfinished and the rim joist is exposed, which makes it the cheapest high-return target in the house. The attic above is often vented with a hatch that does not close properly.
Utility: National Grid, under the Mass Save program
It is worth it where it does two jobs at once, such as a rim joist or a crawlspace wall, because it insulates and air-seals in one pass with a thin layer. On a large flat ceiling it is usually the most expensive way to reach the same R-value, and another material does the job for less.
Thickness is chosen to reach a target R-value for that assembly, not a fixed number of inches. The installer should be able to name the target R-value for each area, the thickness that reaches it, and then show you the measurement.
Yes, in an unvented assembly, and that is the usual fix when an attic has been converted to living space. It has to be full coverage at the right thickness for the climate, and the assembly has to be detailed as unvented rather than left half-vented.